-
Genset Diesel Generator
-
Cummins Diesel Generators
-
Perkins Diesel Generator
-
Small Gasoline Powered Generator
-
Small Diesel Generator
-
Marine Diesel Engines
-
Generator Accessories
-
Deep Sea Control Panel
-
CAT-parts Generator Parts
-
Cummins Generator Parts
-
Uninterruptible Power Supply
-
Atlas Copco Spare Parts
-
FG Wilson Generator Parts
-
Magnetic Door Lock
-
Lovol Generator
-
FG Wilson Control Panel
-
Automatic Voltage Regulators
-
Industrial Hand Cleaner
-
K.S. LIMYour genset and ATS are working well. I have given your name and email to a friend who will be building a hotel in Palawan. Thanks,
-
Waleed-EgyptThanks always giving me good products. thanks for your effort you done before. your firend from Egypt.
-
Akakulubelwa Mwiyakui-ZambiaI must confess you have a brilliant customer relations skills and i am learning from you. I tell you if you want to see how beautiful Zambia in Africa
Household Uninterruptible Power Supply UPS220V Output Tower
Place of Origin | Donggaun,china |
---|---|
Brand Name | GSKA |
Model Number | UPS uninterruptible power supply |
Minimum Order Quantity | negotiation |
Price | negotiation |
Packaging Details | Packed in foam firstly,and then reinforced with strong carton box for outer packing |
Delivery Time | 7-10working days after received deposit |
Supply Ability | 10000 Set / Sets per Month |

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xWave Form | Pure Sinewave | Battery Type | Lead Acid Battery |
---|---|---|---|
Input Voltage | 90-300VAC | Capacity | 10KVA |
Output | 220V ± 10% | AppliCAT-partsion | MEDICAL/Office/Workshop |
Weight | 26 KG | ||
High Light | UPS220V Uninterruptible Power Supply,Pure Sinewave Uninterruptible Power Supply |
Household Uninterruptible Power Supply UPS220V Output Tower
Matters needing attention:
Because of the particularity of its inverter and battery work, the installation and use of UPS power supply must have a set of strict and scientific operating procedures, in order to improve the stability of work, reduce the failure rate of equipment, and truly achieve uninterrupted power supply of equipment.
(1) The installation environment of the UPS power supply should be protected from direct sunlight and have enough ventilation space to ensure that the operating temperature is not higher than 25 ° C. If the operating temperature exceeds 25 ° C, the battery life is reduced by about half for every 10 ° C increase in temperature rise.
(2) It is not suitable to use high-power thyristor load, thyristor bridge rectifier or half-wave rectifier load at the output end of the UPS power supply, which is easy to cause the inverter's final drive transistor to be burned.
(3) Strictly follow the correct startup and shutdown sequence to avoid large fluctuations in the voltage output of the UPS power supply when the load suddenly increases or decreases, so that the UPS power supply cannot work normally.
(4) Do not frequently turn off or on the UPS power supply. Generally, wait at least 30 seconds after turning off the UPS power supply. The cause of frequent UPS power failures is that users start or shut down frequently, and the UPS power supply switches between inverter power supply and bypass power supply with load.
(5) Practice has proved that for the vast majority of UPS power supplies, it is the best working mode to control the load within the range of 50%~60% rated output power. It is forbidden to use over load. The manufacturer suggests that the maximum starting load of UPS power supply should be controlled within 80%. If overload is used, it will often breakdown the inverter triode in the inverter state. Not too light load operation, this situation is easy to cause battery failure because the battery discharge current is too small.
(6) Regularly maintain the UPS power supply: observe the status of the working indiCAT-parts-partsor, remove dust, measure the voltage of the battery, replace the unqualified battery, check the running status of the fan, and detect and adjust the system parameters of the UPS.
(7) UPS power supply is more suitable for with micro capacitive load, not suitable for charged inductive load, such as air conditioning, motor, electric drill, fan, etc. If the UPS power load is resistive or inductive, reduce the load to avoid overload.
Model
|
GSKA-500
|
GSKA-800
|
GSKA-1000
|
GSKA-1500
|
GSKA-2000
|
GSKA-2500
|
GSKA-3000
|
GSKA-5000
|
|
Rated Capacity
|
500VA
|
800VA
|
1000VA
|
1500VA
|
2000VA
|
2500VA
|
3000VA
|
5000VA
|
|
Rated Power
|
300W
|
500W
|
700W
|
1050W
|
1400W
|
1800W
|
2100W
|
3500W
|
|
Transformer
|
Toroidal transformer
|
||||||||
Interface
|
LED graphic
|
||||||||
Display status
|
working&loading&battery
|
||||||||
Working mode
|
PV(Photovoltaic priority)/AC(AC priority) optional
|
||||||||
Input
|
Voltage
|
140-275Vac
|
|||||||
Frequency
|
45-65Hz
|
||||||||
Output
|
Voltage
|
220Vac±3% for inveter; 195v-240V for avr
|
|||||||
Frequency
|
50/60Hz ± 0.3Hz, subject to the main
|
||||||||
Wave Form
|
Pure sine wave
|
||||||||
Wave Distortion
|
≤3%
|
||||||||
Protection
|
overload/high temperature/output high voltage /output low voltage/
battery low voltage shortcircuit/over-charge/over-discharge/reversed polarity(optional) |
||||||||
Transfer Time
|
≤4ms
|
||||||||
Battery Voltage
|
12VDC
|
24VDC
|
48VDC
|
||||||
Charge Voltage
|
13.6V±0.3V
|
27.2V±0.6V
|
54.5V±1V
|
||||||
Low Battery Voltage Limit
|
10.9V±0.3V
|
21.8V±0.5V
|
42V±1V
|
||||||
Protections Battery Low Voltage Protection Point
|
10.2V±0.3V
|
20.5V+0.5V
|
41V±1V
|
||||||
Charge Current
|
Max.10A/15A/20A optional
|
||||||||
Environmental
|
Operating Temperature
|
0~40℃
|
|||||||
Relative Humidity
|
10%~90%RH,non-condensing
|
||||||||
Storage Temperature
|
-15-45℃
|
||||||||
Packing
|
Machine Size(mm)
|
280x144x213
|
385x190x320
|
||||||
Qty/Ctn
|
4
|
4
|
2
|
2
|
1
|
1
|
1
|
1
|
|
Carton Size(mm)
|
785x305x240
|
415x410x245
|
410x290x320
|
||||||
CartonG.W.(kg)
|
22
|
26
|
17.2
|
19.1
|
410x290x321
|



