Genset Diesel Generator
-
Cummins Diesel Generators
-
Perkins Diesel Generator
-
Small Gasoline Powered Generator
-
Small Diesel Generator
-
Marine Diesel Engines
-
Generator Accessories
-
Deep Sea Control Panel
-
CAT-parts Generator Parts
-
Cummins Generator Parts
-
Uninterruptible Power Supply
-
Atlas Copco Spare Parts
-
FG Wilson Generator Parts
-
Magnetic Door Lock
-
Lovol Generator
-
FG Wilson Control Panel
-
Automatic Voltage Regulators
-
Industrial Hand Cleaner
-
K.S. LIMYour genset and ATS are working well. I have given your name and email to a friend who will be building a hotel in Palawan. Thanks,
-
Waleed-EgyptThanks always giving me good products. thanks for your effort you done before. your firend from Egypt.
-
Akakulubelwa Mwiyakui-ZambiaI must confess you have a brilliant customer relations skills and i am learning from you. I tell you if you want to see how beautiful Zambia in Africa
Open Type Cummins Diesel Generators , 4BTA3.9-G2 Silent Generator Set

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xBrand Name | Cummins | Rated Voltage | 400/230V |
---|---|---|---|
Weight | 1320 | Generator Type | Super Silent.Open.Trailer.Container |
Automatic Transfer Switch | SmartGen, Deepsea, Comap | Controller(optional) | Deepsea, Comap, SmartGen |
Engine | Cummins Diesel Engine | Frequency | 50HZ/60HZ |
High Light | ISO9001 Cummins Diesel Generators,4BTA3.9-G2 Silent Generator Set,230V Open Type Genset |
Cummins Diesel Generator 4BTA3.9-G2 Silent Generator Set Open Type Genset
Power calibration:
diesel generator set is a combination of a diesel engine and a synchronous alternator. The maximum power allowed to use diesel engine is limited by the mechanical load and thermal load of parts, so the maximum power allowed to run continuously is called the calibrated power;
Diesel engine can not exceed the calibrated power use, otherwise it will shorten its service life, and may even cause accidents.
According to the national standard, the calibrated power on the diesel nameplate is divided into the following four CAT-parts-partsegories;
1) 15min power: that is, the maximum power allowed to run the diesel engine for 15min. Overload operation may be required in a short time and the calibrated power with acceleration performance is required, such as the calibrated power of diesel engines of automobiles and motorcycles.
2) 1h power: that is, the maximum effective power of the diesel engine allowed to run continuously for 1h. Such as wheeled tractor, locomotive, Marine diesel engine calibration power.
3) 12h power: that is, the maximum effective power of the diesel engine allowed to run continuously for 12h, that is, we often say the rated power. Such as power station unit, engineering machinery with diesel engine calibration power.
4) Continuous power: that is, the maximum power allowed by the diesel engine to run continuously for a long time.
Cummins Technical Parameters(20-60KW)
|
|||||
Genset
|
Model
|
GSKA22S
|
GSKA33S
|
GSKA50S
|
GSKA66S
|
Rated Power(KW/KVA)
|
20/25
|
30/37
|
45/56
|
60/75
|
|
Standby Power(KW/KVA)
|
22/27
|
33/41
|
50/62
|
66/82
|
|
Rated Current(A)
|
36
|
54
|
81
|
108
|
|
weight(kg)
|
1070
|
1320
|
|||
Size(mm)
|
1480*710*1120
|
2250*920*1400
|
|||
Diesel
Engine |
Model
|
4B3.9-G1
|
4BT3.9-G1
|
4BTA3.9-G2
|
4BTA3.9-G11
|
Manufacturer
|
DCEC
|
||||
Continuous Power(KW)
|
24
|
36
|
50
|
70
|
|
Standby Power(KW)
|
26
|
40
|
55
|
80
|
|
Number of Cylinders
|
4
|
||||
Cylinder Diameter*Stroke(mm)
|
102*120
|
||||
Cylinder Arrangement
|
In-line
|
||||
Compression Ratio
|
16.5
|
||||
Displacement(L)
|
3.9
|
||||
Intake Type
|
Exhaust gas turbocharger
|
||||
Cooling Type
|
Tank fan cooling
|
||||
Rated Speed(rpm)
|
1500
|
||||
Fuel Consumption(g/kwh)
|
≤198
|
||||
Discharge Temperature(℃)
|
576
|
||||
Unpitched Sound(db)
|
98
|
||||
Speed Regulation
|
Electronic Speed Regulation
|
||||
Alternator
|
Nominal Voltage(V)
|
400/230
|
|||
Alternator(Optional)
|
Leroy-Somer, Stamford, Engga, Marathon, Elmaer, Wandi, etc.
|
||||
Rated Capacity(KW/KVA)
|
20/25
|
30/37
|
45/56
|
60/75
|
|
Rated Power Factor
|
0.8(lag)
|
||||
Exciter Type
|
Self Excitation Brushless
|
||||
Maximum Voltage Adjustment Rate
|
±1%
|
||||
Phase
|
Three-phase Four-wire
|
||||
Control
Panel |
Control Cabinet Model
|
TBZK880
|
|||
Controller(Optional)
|
SmartGen, Deepsea, Comap
|
||||
Rated Capacity of Circuit Breaker(A)
|
100A
|