• K.S. LIM
    Your genset and ATS are working well. I have given your name and email to a friend who will be building a hotel in Palawan. Thanks,
  • Waleed-Egypt
    Thanks always giving me good products. thanks for your effort you done before. your firend from Egypt.
  • Akakulubelwa Mwiyakui-Zambia
    I must confess you have a brilliant customer relations skills and i am learning from you. I tell you if you want to see how beautiful Zambia in Africa
Contact Person : Kris
Phone Number : 86-13310826672
WhatsApp : +8613310826672

Portable Mini Gasoline Energy Small Electric Variable Frequency Generator 1 Kva

Place of Origin China OEM
Brand Name GSKA
Certification CE,GS,EPA,CARB,CSA
Model Number SF5600i/SF3600i
Minimum Order Quantity 1-5 pieces
Price Negotiable
Packaging Details Standard plywood and wood package.the actual package size against goods size and handle requires. Si
Delivery Time one weeks on receipt of official sales contract
Payment Terms L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal
Supply Ability 500 pieces per Month
Product Details
Rated Current 12V/8.3A Packing 4-colour Carton
Starting System Recoil Start Warrenty 500hours Or 1 Year
Certificate CE, ISO Fuel Unleaded Gasoline
High Light

Mini Gasoline Energy Generator 1Kva

,

12V Electric Variable Frequency Generator

Leave a Message
Product Description

Portable Mini Gasoline Energy Small 1 Kva Electric Variable Frequency Generator


Overheating of bearing:


(1) After a long time of use, bearing wear is excessive, replace the bearing.


(2) The quality of lubricating oil is not good. Different grades of grease are mixed. The grease contains impurities. Remove the old grease and replace it with new grease after cleaning.


(3) Docking with the prime mover is not good strictly to the straight, to find the concentric.


Cause and treatment of easy fire after starting gasoline generator stop:


1. Serious blockage of air filter.


Check the condition of air filter.


2. Circuit failure of electric regulating board, actuator, speed sensor, etc.


3. The oil circuit is not smooth, the filter is blocked, and the oil pump is faulty.


Check the smooth flow of oil, and replace the diesel filter element if necessary.


4, automatic protection function set parameter offset.


Reset parameters.


5, the nozzle fault.


Replace the oil nozzle.


6, automatic unit DC interruption.


Check whether the battery voltage or power supply is sufficient.


There are many forms of generator drive power, the common power machine are:


(1) Wind turbine


Wind turbine is to rely on the wind to drive the generator rotation, generate current; The generator consumes no additional energy and is a pollution-free generator;


(2) hydraulic generator


Hydraulic generator is the use of water flow difference, generate power, drive the generator to generate electricity, is also the use of green natural resources power generation equipment, also known as hydrogenerator


(3) oil-fired generator
 
Product Description:

DIGITAL INVERTER GENERATOR 3.3HP/2KW
Model Number 8896219
Number of phases 1 ph
Maximum power 2kw
Rated power 1.85kw
Voltage/frequency 230v/50hz
Power factor 1
Engine
Max.engine power 2.5kw(3.3hp/5500/min)
Displacement 80cc
Starting recoil
Consumption approx. 0.9 1/kwh
Tank volume 4.5 l
Generator
Type of generator multipole,digital control,inverter.
AC rated current 8.0A/230V
DC rated current 8.3A/12V
Weight 21.6kg
Dimension 42x52x29cm

Portable Mini Gasoline Energy Small Electric Variable Frequency Generator 1 Kva 0Portable Mini Gasoline Energy Small Electric Variable Frequency Generator 1 Kva 1
 
Portable Mini Gasoline Energy Small Electric Variable Frequency Generator 1 Kva 2