K.S. LIMYour genset and ATS are working well. I have given your name and email to a friend who will be building a hotel in Palawan. Thanks,
-
Waleed-EgyptThanks always giving me good products. thanks for your effort you done before. your firend from Egypt.
-
Akakulubelwa Mwiyakui-ZambiaI must confess you have a brilliant customer relations skills and i am learning from you. I tell you if you want to see how beautiful Zambia in Africa
Super Silent Small Diesel Generator Portable 110V 220v/380v
Place of Origin | China OEM |
---|---|
Brand Name | GSKA |
Model Number | BC8500/BC8500T, BC10000/BC10000T,BC12000/BC12000T |
Minimum Order Quantity | 1-5 pieces |
Price | Negotiable |
Packaging Details | Standard plywood and wood package.the actual package size against goods size and handle requires. Si |
Delivery Time | one weeks on receipt of official sales contract |
Payment Terms | L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal |
Supply Ability | 500 pieces per Month |

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xCertifiCAT-partsion | ISO9001 | Frequency | 50hz/60hz |
---|---|---|---|
Alternator | Brushless Self-excited | Controller | SmartGen, Deepsea, Etc |
Cooling Method | Automatic Transfer Switch | Phase | 1 Phase/3 Phase |
Noise | 75dB | ||
High Light | Silent Small Diesel Generator,220v Small Diesel Generator |
Super Silent Small Portable Diesel Generator 110V 220v/380v
Front appliCAT-parts-partsion:
1. Coordinated control of battery energy storage and diesel generator in independent AC microgrid
In the independent AC microgrid system, the coordination control between the diesel generator and the battery energy storage is the key to ensure the stable operation of the system. Based on the fast response characteristic of battery energy storage, a coordinated control method of diesel generator and energy storage battery was proposed. When the diesel generator is used as the main power supply, the auxiliary power control signal is introduced into the traditional droop control of the energy storage system to prevent the system collapse caused by the diesel engine overcurrent for a long time and improve the system stability. Aiming at the short-time power outage problem when the main power supply in the microgrid changes from the energy storage system to the diesel generator or from the diesel generator to the energy storage system, a seamless switching control strategy of the two main power supplies of the diesel generator and the energy storage battery is proposed.
Power generation and Knowledge:
Composition of generator; There are three main parts, the engine, the electric ball and the controller. It's a four stroke. There is water cooling, air cooling.
Regulating characteristics:
Voltage regulation and frequency regulation are different: in a system, the frequency value is the same regardless of the region, the balance of active power is the balance of the whole system; The voltage level is not consistent in different areas of electricity consumption, reactive power balance is mainly in different areas of balance, power plant voltage regulation ability can only reach a small area around it.. Generator in parallel operation, more of a unit used this method to adjust the function of frequency and voltage for the system was not significant, it mainly is to adjust the load distribution between the group, especially in a large system of small units, output size not happen a material impact on voltage and frequency, can be adjusted according to the need of unit. So the regulation of a small generator connected to the grid is much simpler.
When the active power output of the generator is maintained unchanged, the reactive power output and power factor of the generator can be changed by changing the excitation. When the excitation current remains unchanged, increase the active power output, the reactive power output of the generator will decrease, if it is not reduced, it must increase the excitation accordingly.
GENERATOR | Model | GSKA-8500SE | |
Frequency(HZ) | 50 | 60 | |
Max. output(kw) | 6.5 | 7.0 | |
Rated output(kw) | 6 | 6.5 | |
Rated. AC voltage(v) | 120, 220, 230, 240 | ||
Power factor(cosΦ ) | cosΦ =1 | ||
DC output (v) | 12V/8.3A | ||
Phase | Single phase | ||
Alternator type | self-excited, 2-pole, single phase alternator | ||
Starting system | Electric | ||
Operating noise level(at 7m) | 68~72 | ||
Fuel tank capacity(L) | 16 | ||
Continues work(hr) | 7.8 | 7.4 | |
ENGINE | Model | HR192FB | |
Engine type | Single-cylinder, vertical, 4-stroke air-cooled diesel engine | ||
Bore× stroke(mm) | 92×75 | ||
Fuel | 0# or -10# light diesel fuel | ||
LubriCAT-parts-partsion oil volume(L) | 1.65 | ||
Combustion system | Direct lnjection | ||
STANDARD FEATURES | Voltmeter | yes | |
AC Output Socket | 2 | ||
AC circuit breaker | yes | ||
Oil warning light | yes | ||
Oil alert | yes | ||
OPTIONAL FEATURES | DC circuit breaker | optional | |
Calculagraph | optional | ||
Big Wheel | optional | ||
Three phase voltage | optional | ||
Current meter | optional | ||
ATS | optional | ||
Remote control | optional | ||
Welding | optional | ||
DIMENSIONS | Dimension(L× W× H)(mm) | 910× 535× 700 | |
Net weight(kg) | 155 | ||
20FT | 72 |