750 kVA 60 Hz Perkins Diesel Generators , 3 Pole ACB / MCCB

Place of Origin China
Brand Name GSKA
Model Number JP-P800E1
Minimum Order Quantity 20-30 pieces
Price Negotiable
Packaging Details Standard plywood and wood package.the actual package size against goods size and handle requires.
Delivery Time 3-5 days on receipt of official sales contract
Payment Terms L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal
Supply Ability 500 pieces per Month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
High Light

standby diesel generator

,

portable diesel powered generators

Leave a Message
Product Description

 

1, Engine Make & Model:                  Perkins 4006TAG2A

2,Generating Set Model:                            P800E1

3,Alternator Model:                                    LL7024L

4, Circuit Breaker Type:                     3 Pole ACB/MCCB

5, Frequency:                                        50 Hz / 60 Hz

6,Cycle:                                                    4 Stroke

7, Engine Speed:                              1500rpm/1800rpm

8, Cooling Method:                       Turbo, Water/Air cooling

9, Governing Type:                                  Electronic

10, Output Type:                                AC Three Phase

10, No.of Cylinders/Alignment:                 6 / In Line

11,Base Frame Type:                Heavy Duty FabriCAT-parts-partsed Steel

 

750 kVA 60 Hz Perkins Diesel Generators , 3 Pole ACB / MCCB

Output Ratings

Generating Set Model

*                               P800E1

Prime*                     Standby*

380-415V, 50 Hz

730.0 kVA                800.0 kVA

584.0 kW                 640.0 kW

480V, 60 Hz

750.0 kVA                844.0 kVA

600.0 kW                 675.2 kW

  • Refer to ratings definitions on page 4.

             Ratings at 0.8 power factor.

 

Technical Data

Engine Make & Model:

Perkins 4006TAG2A

Alternator Model:

LL7024L

Base Frame Type:

Heavy Duty FabriCAT-parts-partsed Steel

Circuit Breaker Type:

3 Pole ACB/MCCB

Frequency:

50 Hz           60 Hz

Engine Speed: RPM

1500                1800

Fuel Tank Capacity: litres (US gal)

1494 (394.7)

Fuel Consumption:   P730P1   l/hr (US gal/hr)

149.8 (39.6)     167.0 (44.1)

Fuel Consumption:   P800E1    l/hr (US gal/hr)

163.4 (43.2)     189.1 (50.0)

P730P1 / P800E1

 

Engine Technical Data

Physical Data 

 

Manufacturer:                                                             Perkins

Model:                                                                    4006TAG2A

No. of Cylinders/Alignment:                                      6 / In Line

Cycle:                                                                       4 Stroke

Induction:                                                              Turbocharged

Air To Air Charge Cooled

Cooling Method:                                                         Water

Governing Type:                                                      Electronic

Governing Class:                                                   ISO 8528 G2

Compression Ratio:                                                    13.6:1

Displacement: l (cu.in)                                          22.9 (1398.7)

Bore/Stroke: mm (in)                                     160.0 (6.3)/190.0 (7.5)

Moment of Inertia: kg m² (lb. in²)                          10.61 (36256)

Engine Electrical System:

-Voltage/Ground:                                                   24/Negative

-Battery Charger Amps:                                               40

Weight: kg (lb)

- Dry:                                                                    2524 (5564)

- Wet:                                                                   2663 (5871)

 

Air System  

 

Air Filter Type:                                                    Replaceable

Element Combustion Air Flow:

m³/min (cfm)        -Standby:                                 71.0 (2507)                          73.0 (2578)

-Prime:                                                                 64.0 (2260)                         65.0 (2295)

Max. Combustion Air Intake

Restriction: kPa (in H2O)                                        3.7 (14.9)                            3.7 (14.9)

Radiator Cooling Air Flow:

m³/min (cfm)                                                   1134.0 (40047)                   1326.0 (46827)

External Restriction to

Cooling Air Flow: Pa (in H2O)                                  250 (1.0)                             250 (1.0)

Cooling System                                                        50 Hz                                  60 Hz

Cooling System Capacity:

l (US gal)                                                              105.0 (27.7)                       105.0 (27.7)

Water Pump Type:                                                                   Centrifugal

Heat Rejected to Water & Lube Oil: kW (Btu/min)

-Standby:                                                          230.0 (13080)                 243.0 (13819)

-Prime:                                                              191.0 (10862)                 200.0 (11374)

Heat Radiation to Room:

kW (Btu/min)        -Standby:                                  88.7 (5044)                     98.9 (5624)

-Prime:                                                                  83.7 (4760)                     93.9 (5340)

Radiator Fan Load: kW (hp)                                  26.0 (34.9)                      44.0 (59.0)

Cooling system designed to operate in ambient conditions up to 50°C (122°F).

Contact your local FG Wilson dealer for power ratings at specific site conditions.

Performance                                 50 Hz                                                      60 Hz

 

Engine Speed: RPM                        1500                                                       1800

Gross Engine Power: kW (hp)

-Standby:                                  711.0 (953.0)                                         759.0 (1018.0)

-Prime:                                      646.0 (866.0)                                           684.0 (917.0)

BMEP: kPa (psi)

-Standby:                                2481.0 (359.9)                                         2208.0 (320.2)

-Prime:                                    2255.0 (327.0)                                         1989.0 (288.5)

Regenerative Power: kW                  70.0                                                         75.0

 

LubriCAT-parts-partsion System

Oil Filter Type:                                                 Spin-On, Full Flow

Total Oil Capacity l (US gal):                               123.0 (32.5)

Oil Pan l (US gal):                                               113.4 (30.0)

Oil Type:                                                          API CG4 15W-40

Cooling Method:                                                     Water

 

Exhaust System                           50 Hz                                                        60 Hz

Silencer Type:                                                                                        Level 1

Silencer Model & Qty:                                                                           SD250 (1)

Pressure Drop Across Silencer System: kPa (in Hg)     1.20 (0.354)                      0.22 (0.065)

Silencer Noise Reduction Level: dB                                    20                                        16

Max. Allowable Back Pressure: kPa (in. Hg)                     6.0 (1.8)                            6.0 (1.8)

Exhaust Gas Flow: m³/min (cfm)       

-Standby:                                                                      180.0 (6357)                    190.0 (6710)

-Prime:                                                                          180.0 (6357)                    190.0 (6710)

Exhaust Gas Temperature:  °C (°F)

m³/min (cfm)       

-Standby:                                                                          430 (806)                       430 (806)

-Prime:                                                                              430 (806)                       430 (806)

 

Fuel System

Fuel Filter Type:                            Replaceable Element Recommended

Fuel:                                                               Class A2 Diesel

Fuel Consumption: l/hr (US gal/hr)

110%              100%               75%                50%

Load               Load               Load               Load

P730P1

50 Hz       164.0 (43.3)    149.8 (39.6)    114.8 (30.3)   81.6 (21.6)

60 Hz       189.1 (50.0)    167.0 (44.1)    124.7 (32.9)   89.9 (23.7)

P800E1

50 Hz   163.4 (43.2)    124.7 (32.9)  87.9 (23.2)

60 Hz  189.1 (50.0)    139.9 (37.0)  97.8 (25.8)

(based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)

P730P1 / P800E1

 

Alternator Performance Data

Data Item

50 Hz                                                            60 Hz

415/240V

400/230V

380/220V

480/277V

380/220V

440/254V

Motor Starting Capability* kVA

2096

1962

1789

2307

1514

1977

Short Circuit Capacity** %

300

300

300

300

300

300

Reactances: Per Unit

Xd X'd X''d

2.800

 

0.140

 

0.110

3.020

 

0.150

 

0.118

3.340

 

0.160

 

0.131

2.580

 

0.130

 

0.101

4.040

 

0.200

 

0.158

3.070

 

0.150

 

0.120

Reactances shown are applicable to prime ratings

  • Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.

** With optional Permanent Magnet generator or AREP excitation.

 

Alternator Technical Data

Physical Data                                                                   Operating Data

Manufacturer:  FG WILSON

Overspeed: RPM2250

Model:  LL7024L

Voltage Regulation (steady state) (%): + /- 0.5

No. of Bearings:   1

Wave Form NEMA = TIF:    50

Insulation Class:      H

Wave Form IEC = THF:     2.0%

Winding Pitch Code:   2/3 - 6S

Total Harmonic Content LL/LN:   4.0%

Wires:   6

Supression is in line with European Standard Radio Interference:       EN61000-6

Ingress Protection Rating:   IP23

Radiant Heat: kW (Btu/min)

-50 Hz:                                  38.7 (2201)

-60 Hz:                                  43.9 (2497)

Excitation System:  AREP

AVR Model: R448

P730P1 / P800E1

 

Technical Data

3 Phase Ratings and Performance at 50 Hz, 1500 RPM

3 Phase Ratings and Performance at 60 Hz, 1800 RPM

Voltage         Prime Model    Standby Model     Voltage      Prime Model        Standby Model

                       P730P1           P800E1                               P730P1              P800E1

 

kVA                 kW

kVA                 kW

 

kVA                 kW

kVA                  kW

415/240V

730.0              584.0

800.0              640.0

480/277V

750.0              600.0

844.0              675.2

400/230V

730.0              584.0

800.0              640.0

 

 

 

380/220V

730.0              584.0

800.0              640.0

380/220V

735.0              588.0

810.0              648.0

 

 

 

440/254V

-                      -

-                      -

Definitions

 

Standby Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).

 

 

Prime Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

 

 

Standard Reference Conditions

Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.

 

750 kVA 60 Hz Perkins Diesel Generators , 3 Pole ACB / MCCB 0

 

Weights and Dimensions

 

Weights: kg (lb)                                                             Dimensions: mm (in

Net (+ lube oil)

6059 (13358)

Length

4280 (168.5)

Wet (+ lube oil & coolant)

6170 (13603)

Width

1912 (75.3)

Fuel, lube oil & coolant

6330 (13955)

Height

2277 (89.6)

 

General Data

Documents

A full set of operation and maintenance manuals, circuit wiring diagrams, and commissioning/fault finding instruction leaflets.

 

 

Generating Set Standards

The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, VDE 0530, NEMA MG-1.22.

 


Warranty

All equipment carries full manufacturer's warranty.