Genset Diesel Generator
-
Cummins Diesel Generators
-
Perkins Diesel Generator
-
Small Gasoline Powered Generator
-
Small Diesel Generator
-
Marine Diesel Engines
-
Generator Accessories
-
Deep Sea Control Panel
-
CAT-parts Generator Parts
-
Cummins Generator Parts
-
Uninterruptible Power Supply
-
Atlas Copco Spare Parts
-
FG Wilson Generator Parts
-
Magnetic Door Lock
-
Lovol Generator
-
FG Wilson Control Panel
-
Automatic Voltage Regulators
-
Industrial Hand Cleaner
-
K.S. LIMYour genset and ATS are working well. I have given your name and email to a friend who will be building a hotel in Palawan. Thanks,
-
Waleed-EgyptThanks always giving me good products. thanks for your effort you done before. your firend from Egypt.
-
Akakulubelwa Mwiyakui-ZambiaI must confess you have a brilliant customer relations skills and i am learning from you. I tell you if you want to see how beautiful Zambia in Africa
Soundproof Perkins Diesel Generator , 2806A-E18TAG1A
Place of Origin | China |
---|---|
Brand Name | GSKA |
Model Number | JP-P660E5 |
Minimum Order Quantity | 20-30 pieces |
Price | Negotiable |
Packaging Details | Standard plywood and wood package.the actual package size against goods size and handle requires. |
Delivery Time | 3-5 days on receipt of official sales contract |
Payment Terms | L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal |
Supply Ability | 500 pieces per Month |

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xHigh Light | diesel generators sets,portable diesel powered generators |
---|
1.Standby power: 528.0 KW
2.Engine Make & Model: Perkins 2806A-E18TAG1A
3.Alternator Model: LL6114K
4.Water Governing Type: Electronic Governing
5.Class: ISO 8528 G2
6.Compression Ratio: 14.5:1
7.Displacement: l (cu.in) 18.1
Soundproof Perkins Diesel Generator , 2806A-E18TAG1A
Output Ratings |
|
Generating Set Model |
* P660E5 Prime* Standby* |
380-415V,50Hz |
600.0 kVA 660.0 kVA 480.0 kW 528.0 kW |
220/127V, 60 Hz |
- - - - |
- Refer to ratings definitions on page 4.
Ratings at 0.8 power factor.
Technical Data |
|
Engine Make & Model: |
Perkins 2806A-E18TAG1A |
Alternator Model: |
LL6114K |
Base Frame Type: |
Heavy Duty FabriCAT-parts-partsed Steel |
Circuit Breaker Type: |
3 Pole ACB/MCCB |
Frequency: |
50 Hz 60 Hz |
Engine Speed: RPM |
1500 - |
Fuel Tank Capacity: litres (US gal) |
1000 (264.2) |
Fuel Consumption P600P5 : l/hr (US gal/hr) |
118.4 (31.3) - |
Fuel Consumption P660E5 : l/hr (US gal/hr) |
131.1 (34.6) - |
P600P5 / P660E5
Engine Technical Data
Physical Data
Manufacturer: Perkins
Model: 2806 A-E18TAG1A
No. of Cylinders/Alignment: 6 / In Line
Cycle: 4 Stroke
Induction: Turbo charged Air To Air Charge Cooled
Cooling Method: Water
Governing Type: Electronic Governing
Class: ISO 8528 G2
Compression Ratio: 14.5:1
Displacement: l (cu.in) 18.1 (1104.5)
Bore/Stroke: mm (in) 145.0 (5.7)/183.0
(7.2) Moment of Inertia: kg m² (lb. in²) 7.44 (25424)
Engine Electrical System:
-Voltage/Ground: 24/Negative
-Battery Charger Amps: 70
Weight: kg (lb)
- Dry: 2050 (4519)
- Wet: 2158 (4758)
Air System 50 Hz 60 Hz
Air Filter Type: Replaceable
Element Combustion Air Flow:m³/min (cfm)
-Standby: 34.3 (1211)
-Prime: 32.4 (1144)
- Max. Combustion Air Intake
Restriction: kPa (in H2O) 6.3 (25.3)
- Radiator Cooling Air Flow:
m³/min (cfm) 660.0 (23308)
- External Restriction to
Cooling Air Flow: Pa (in H2O) 125 (0.5)
Cooling System 50 Hz 60 Hz
Cooling System Capacity:
l (US gal) 61.0 (16.1)
- Water Pump Type: Centrifugal Heat Rejected to Water & Lube
Oil: kW (Btu/min)
-Standby: 210.0 (11942)
-Prime: 197.0 (11203)
- Heat Radiation to Room:
kW (Btu/min) -Standby: 38.0 (2161)
-Prime: 35.0 (1990)
- Radiator Fan Load: kW (hp) 8.0 (10.7)
Cooling system designed to operate in ambient conditions up to 50°C (122°F). Contact your local FG Wilson dealer for power ratings at specific site conditions.
Performance 50 Hz 60 Hz
Engine Speed: RPM 1500
- Gross Engine Power: kW (hp)
-Standby: 592.7 (795.0)
-Prime: 539.7 (724.0)
- BMEP: kPa (psi)
-Standby: 2615.0 (379.3)
-Prime: 2381.0 (345.4)
- Regenerative Power: kW 20.0
LubriCAT-parts-partsion System
Oil Filter Type: Eco, Full Flow
Total Oil Capacity l (US gal): 55.5 (14.7)
Oil Pan l (US gal): 53.5 (14.1)
Oil Type: API CH4 / CI4
Cooling Method: Water
Fuel System
Fuel Filter Type: Eco Replaceable Element Recommended
Fuel: Class A2 Diesel
Fuel Consumption: l/hr (US gal/hr)
110% 100% 75% 50% Load Load Load Load
P600P5
50 Hz 131.0 (34.6) 118.4 (31.3) 88.8 (23.5) 61.0 (16.1)
P660E5
50 Hz 131.1 (34.6) 97.7 (25.8) 66.5 (17.6)
60 Hz - - -
(based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)
Exhaust System 50 Hz 60 Hz
Silencer Type: Level 1
Silencer Model & Qty: SD200 (1)
Pressure Drop Across Silencer System: kPa (in Hg) 0.25 (0.074)
- Silencer Noise Reduction Level: dB 14
- Max. Allowable Back Pressure: kPa (in. Hg) 6.8 (2.0)
- Exhaust Gas Flow:m³/min (cfm)
-Standby: 123.0 (4344)
-Prime: 123.0 (4344)
- Exhaust Gas Temperature: °C (°F)
m³/min (cfm)
-Standby: 563 (1045)
-Prime: 563 (1045)
P600P5 / P660E5
Alternator Performance Data
Data Item |
50 Hz |
||
415/240V |
400/230V |
380/220V |
|
Motor Starting Capability* kVA |
1525 |
1427 |
1301 |
Short Circuit Capacity** % |
300 |
300 |
300 |
Reactances: Per Unit
Xd X'd X''d |
3.020
0.150
0.105 |
3.250
0.160
0.114 |
3.600
0.180
0.126 |
Reactances shown are applicable to prime ratings
- Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.
** With optional Permanent Magnet generator or AREP excitation.
Alternator Technical Data
Physical Data Operating Data |
|
Manufacturer: FG WILSON |
Overspeed: RPM 2250 |
Model: LL6114K |
Voltage Regulation (steady state) (%): +/- 0.5 |
No. of Bearings: 1 |
Wave Form NEMA = TIF: 50 |
Insulation Class: H |
Wave Form IEC = THF: 2.0% |
Winding Pitch Code: 2/3 - 6S |
Total Harmonic Content LL/LN: 2.0% |
Wires: 6 |
Supression is in line with European Standard Radio Interference: EN61000-6 |
Ingress Protection Rating: IP23 |
Radiant Heat: kW (Btu/min) -50 Hz: 31.3 (1780) -60 Hz: - |
Excitation System: SHUNT |
|
AVR Model: R448 |
P600P5 / P660E5
Technical Data
3 Phase Ratings and Performance at 50 Hz, 1500 RPM
3 Phase Ratings and Performance at 60 Hz,- RPM
Definitions
Standby Rating
These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).
Prime Rating
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Standard Reference Conditions
Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.
Weights and Dimensions
Weights: kg (lb) Dimensions: mm (in)
Net (+ lube oil) |
4717 (10399) |
Length |
4111 (161.9) |
Wet (+ lube oil & coolant) |
4787 (10554) |
Width |
1536 (60.5) |
Fuel, lube oil & coolant |
5928 (13069) |
Height |
2246 (88.4) |
General Data
Documents
A full set of operation and maintenance manuals, circuit wiring diagrams, and commissioning/fault finding instruction leaflets.
Generating Set Standards
The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, VDE 0530, NEMA MG-1.22.
Warranty
All equipment carries full manufacturer's warranty.