120kW Water Cooled Perkins Diesel Generator , 1006TAG2

Place of Origin China
Brand Name GSKA
Model Number JP-P165E1
Minimum Order Quantity 20-30 pieces
Price Negotiable
Packaging Details Standard plywood and wood package.the actual package size against goods size and handle requires.
Delivery Time 3-5 days on receipt of official sales contract
Payment Terms L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal
Supply Ability 500 pieces per Month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
High Light

diesel generators sets

,

portable diesel powered generators

Leave a Message
Product Description

 

Standby power:                                 132 KW

Engine Make & Model:              Perkins 1006TAG2

Alternator Model:                             LL3014H

Circuit Breaker Type:                   3 Pole MCCB

No. of Cylinders/Alignment:             6 / In Line

Type:                                      Electronic Governing 

Class:                                            ISO 8528 G2

Compression Ratio:                            17.0:1

Displacement: l (cu.in)                    6.0 (365.5) 

Bore/Stroke: mm (in)              100.0 (3.9)/127.0 (5.0) 

Moment of Inertia: kg m² (lb. in²)      1.61 (5502) 

 

Water Cooled Perkins Diesel Generator , 1006TAG2

 

Output Ratings

Generating Set Model

 

*   JPP165E1

Prime*                     Standby*

380-415V, 50 Hz

150.0 kVA                165.0 kVA

120.0 kW                 132.0 kW

220/127V, 60 Hz

-                               -

-                               -

  • Refer to ratings definitions on page 4.

            Ratings at 0.8 power factor.


 

Technical Data

Engine Make & Model:

Perkins 1006TAG2

Alternator Model:

LL3014H

Base Frame Type:

Heavy Duty FabriCAT-parts-partsed Steel

Circuit Breaker Type:

3 Pole MCCB

Frequency:

50 Hz           60 Hz

Engine Speed: RPM

1500                   -

Fuel Tank Capacity: litres (US gal)

300 (79.3)

Fuel Consumption:   P150P1   l/hr (US gal/hr)

31.2 (8.2)                -

Fuel Consumption:   P165E1    l/hr (US gal/hr)

33.5 (8.8)                -

 

P150P1 / P165E1

 

Engine Technical Data

 

Physical Data

Manufacturer:                                    Perkins

Model:                                            1006TAG2

No. of Cylinders/Alignment:             6 / In Line

Cycle:                                               4 Stroke

Induction:                   Turbocharged Air To Air Charge Cooled 

Cooling Method:                                Water

Governing Type:                     Electronic Governing

Class:                                           ISO 8528 G2

Compression Ratio:                          17.0:1

Displacement: l (cu.in)                   6.0 (365.5)

Bore/Stroke: mm (in)             100.0 (3.9)/127.0 (5.0)

Moment of Inertia: kg m² (lb. in²)       1.61 (5502)

Engine Electrical System:

-Voltage/Ground:                             12/Negative

-Battery Charger Amps:                          55

Weight: kg (lb)

- Dry:                                                586 (1292)

- Wet:                                               630 (1389)

 

Air System                                    50 Hz                                                        60 Hz

 

Air Filter Type:                                                          Replaceable

Element Combustion Air Flow: m³/min (cfm)       

-Standby:                                   10.6 (374)               -

-Prime:                                       10.2 (360)              

- Max. Combustion Air Intake

Restriction: kPa (in H2O)             5.0 (20.1)               

- Radiator Cooling Air Flow: m³/min (cfm)                   221.2 (7811)            

- External Restriction to Cooling Air Flow: Pa (in H2O)  125 (0.5)          

 

 

Cooling System                            50 Hz                                                       60 Hz

 

Cooling System Capacity: l (US gal) 40.2 (10.6)              

- Water Pump Type:                                                       Centrifugal

Heat Rejected to Water & Lube Oil: kW (Btu/min)

-Standby:                                                                      72.9 (4146)              

-Prime:                                                                          64.6 (3674)              

- Heat Radiation to Room:kW (Btu/min)        

-Standby:                                                                      42.9 (2440)              

-Prime:                                                                          27.7 (1575)              

- Radiator Fan Load: kW (hp)                                            7.0 (9.4)               

Cooling system designed to operate in ambient conditions up to 50°C (122°F).

 

 

Performance                                50 Hz                                                        60 Hz

 

Engine Speed: RPM                      1500                      

- Gross Engine Power: kW (hp)

-Standby:                                 150.7 (202.0)                                                      -

-Prime:                                     137.0 (184.0)               

- BMEP: kPa (psi)

-Standby:                               2015.0 (292.2)                                                      -

-Prime:                                   1831.0 (265.6)               

- Regenerative Power: kW  

 

 

LubriCAT-parts-partsion System

 

Oil Filter Type:                                           Spin-On, Full Flow

Total Oil Capacity l (US gal):                            19.0 (5.0)

Oil Pan l (US gal):                                            16.0 (4.2)

Oil Type:                                                     API CG4 15W-40

Cooling Method:                                                  Water

 

Fuel System

 

Fuel Filter Type:                                            Replaceable

Element Recommended Fuel:                    Class A2 Diesel

Fuel Consumption: l/hr (US gal/hr)

 

110%              100%               75%                50%

Load               Load               Load               Load

P150P1

 

50 Hz         33.5 (8.8)        31.2 (8.2)        26.4 (7.0)               -

60 Hz                 -                      -                       -                      -

P165E1

 

50 Hz                                 33.5 (8.8)        27.8 (7.3)               -

60 Hz                                        -                       -                      -

 

(based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)

 

 

Exhaust System                           50 Hz                                                        60 Hz

 

Silencer Type:                                                               Level 1

Silencer Model & Qty:                                                 SD100 (1)

Pressure Drop Across

Silencer System: kPa (in Hg)                                   3.31 (0.977)             

- Silencer Noise Reduction

Level: dB                                                                         20                     

- Max. Allowable Back

Pressure: kPa (in. Hg)                                                4.0 (1.2)                

- Exhaust Gas Flow:

m³/min (cfm)       

-Standby:                                    29.9 (1056)                                                    -

-Prime:                                          28.3 (999)              

- Exhaust Gas Temperature:  °C (°F)

m³/min (cfm)       

-Standby:                                     540 (1004)                                                     -

-Prime:                                           530 (986)                                                     -

P150P1 / P165E1

 

 

Alternator Performance Data

Data Item

50 Hz                                                            60 Hz

415/240V

400/230V

230/115V

200/115V

380/220V

220/110V

220/127V

Motor Starting Capability* kVA

384

361

331

423

Short Circuit Capacity** %

300

300

300

30

Reactances: Per Unit

 

 

Xd X'd X''d

2.580

 

0.090

 

0.052

2.780

 

0.090

 

0.056

3.080

 

0.100

 

0.062

2.150

 

0.070

 

0.043

 

 

Reactances shown are applicable to prime ratings

  • Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.

** With optional Permanent Magnet generator or AREP excitation.

 

 

Alternator Technical Data

 

Physical Data                                                                   Operating Data

Manufacturer:   FG WILSON

Overspeed: RPM      2250

Model:       LL3014H

Voltage Regulation (steady state) (%):  + /- 0.5

No. of Bearings:     1

Wave Form NEMA = TIF:   50

Insulation Class:H

Wave Form IEC = THF:2.0%

Winding Pitch Code: 2/3 - 6

Total Harmonic Content LL/LN:  4.0%

Wires:  12

Supression is in line with European Standard

Radio Interference:       EN61000-6

Ingress Protection Rating:   IP23

Radiant Heat: kW (Btu/min)

-50 Hz:                                   11.0 (626)

-60 Hz:                                           -

Excitation System:    SHUNT

AVR Model: R230

P150P1 / P165E1

 

Technical Data

 

3 Phase Ratings and Performance at 50 Hz, 1500 RPM


3 Phase Ratings and Performance at 60 Hz,

-    RPM

 

 

Voltage         Prime Model         Standby Model          Voltage          Prime Model            Standby Model

                      P150P1                        P165E1                                  -                                  -

 

kVA                 kW

kVA                 kW

 

kVA                 kW

kVA                  kW

415/240V

150.0              120.0

165.0              132.0

 

 

 

400/230V

150.0              120.0

165.0              132.0

 

 

 

380/220V

150.0              120.0

165.0              132.0

 

 

 

230/115V

150.0              120.0

165.0              132.0

 

 

 

220/127V

140.0              112.0

154.0              123.2

 

 

 

220/110V

150.0              120.0

165.0              132.0

 

 

 

200/115V

150.0              120.0

165.0              132.0

 

 

 

 

 

 

230/115V

-                      -

-                      -

 

 

Definitions

Standby Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).


 

Prime Rating

 

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.


 

Standard Reference Conditions

Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.

 

 

120kW Water Cooled Perkins Diesel Generator , 1006TAG2 0

 

 

Weights and Dimensions

 

Weights: kg (lb)                                                             Dimensions: mm (in)

 

 

Net (+ lube oil)

 

1515 (3340)

 

Length

 

2675 (105.3)

Wet (+ lube oil & coolant)

1535 (3384)

Width

900 (35.4)

Fuel, lube oil & coolant

1602 (3532)

Height

1564 (61.6)

 

 

General Data

Documents

A full set of operation and maintenance manuals, circuit wiring diagrams, and commissioning/fault finding instruction leaflets.

 

 

Generating Set Standards

The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, VDE 0530, NEMA MG-1.22.

 

 

Warranty

All equipment carries full manufacturer's warranty.