Genset Diesel Generator
-
Cummins Diesel Generators
-
Perkins Diesel Generator
-
Small Gasoline Powered Generator
-
Small Diesel Generator
-
Marine Diesel Engines
-
Generator Accessories
-
Deep Sea Control Panel
-
CAT-parts Generator Parts
-
Cummins Generator Parts
-
Uninterruptible Power Supply
-
Atlas Copco Spare Parts
-
FG Wilson Generator Parts
-
Magnetic Door Lock
-
Lovol Generator
-
FG Wilson Control Panel
-
Automatic Voltage Regulators
-
Industrial Hand Cleaner
-
K.S. LIMYour genset and ATS are working well. I have given your name and email to a friend who will be building a hotel in Palawan. Thanks,
-
Waleed-EgyptThanks always giving me good products. thanks for your effort you done before. your firend from Egypt.
-
Akakulubelwa Mwiyakui-ZambiaI must confess you have a brilliant customer relations skills and i am learning from you. I tell you if you want to see how beautiful Zambia in Africa
1800 rpm Diesel Generator , 60 hz , Perkins 1006TG2A , Turbocharged
Place of Origin | China |
---|---|
Brand Name | GSKA |
Model Number | JP- P110E |
Minimum Order Quantity | 20-30 pieces |
Price | Negotiable |
Packaging Details | Standard plywood and wood package.the actual package size against goods size and handle requires. |
Delivery Time | 3-5 days on receipt of official sales contract |
Payment Terms | L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal |
Supply Ability | 500 pieces per Month |

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xHigh Light | standby diesel generator,diesel generators sets |
---|
Manufacturer: Perkins
Model: 1006TG2A
No. of Cylinders/Alignment: 6 / In Line
Cycle: 4 Stroke
Induction: Turbocharged
Cooling Method: Water
Governing Type: Mechanical
Governing Class: ISO 8528 G2
Compression Ratio: 16.0:1
Output Ratings |
||
Generating Set Model |
* JPP110E Prime* Standby* |
|
380-415V, 50 Hz |
100.0 kVA 110.0 kVA 80.0 kW 88.0 kW |
|
480V, 60 Hz |
113.0 kVA 125.0 kVA 90.4 kW 100.0 kW |
* Refer to ratings definitions on page 4.
Ratings at 0.8 power factor.
Technical Data |
|
Engine Make & Model: |
Perkins 1006TG2A |
Alternator Model: |
LL3014B |
Base Frame Type: |
Heavy Duty FabriCAT-parts-partsed Steel |
Circuit Breaker Type: |
3 Pole MCB / 3 Pole MCCB |
Frequency: |
50 Hz 60 Hz |
Engine Speed: RPM |
1500 1800 |
Fuel Tank Capacity: litres (US gal) |
230 (60.8) |
Fuel Consumption: P100 l/hr (US gal/hr) |
22.8 (6.0) 26.4 (7.0) |
Fuel Consumption: P110E l/hr (US gal/hr) |
25.4 (6.7) 29.2 (7.7) |
P100 / P110E
Engine Technical Data
Physical Data
Manufacturer: Perkins
Model: 1006TG2A
No. of Cylinders/Alignment: 6 / In Line
Cycle: 4 Stroke
Induction: Turbocharged
Cooling Method: Water
Governing Type: Mechanical
Governing Class: ISO 8528 G2
Compression Ratio: 16.0:1
Displacement: l (cu.in) 6.0 (365.5)
Bore/Stroke: mm (in) 100.0 (3.9)/127.0 (5.0)
Moment of Inertia: kg m² (lb. in²) 1.61 (5502)
Engine Electrical System:
-Voltage/Ground: 12/Negative-Battery Charger Amps: 55
Weight: kg (lb) - Dry: 586 (1292)- Wet: 623 (1373)
Air System 50 Hz 60 Hz
Air Filter Type: Replaceable
Element Combustion Air Flow:m³/min (cfm)
-Standby: 6.0 (212) 7.6 (268)
-Prime: 5.7 (201) 7.2 (254)
Max. Combustion Air Intake
Restriction: kPa (in H2O) 5.0 (20.1) 5.0 (20.1)
Radiator Cooling Air Flow:m³/min (cfm) 192.0 (6780) 244.0 (8617)
External Restriction to Cooling Air Flow: Pa (in H2O) 125 (0.5) 125 (0.5)
Cooling System 50Hz 60 Hz
Cooling System Capacity: l (US gal) 27.7 (7.3) 27.7 (7.3)
Water Pump Type: Centrifugal
Heat Rejected to Water & Lube Oil: kW (Btu/min)
-Standby: 69.8 (3969) 78.8 (4481)
-Prime: 62.6 (3560) 70.8 (4026)
Heat Radiation to Room:
kW (Btu/min) -Standby: 48.3 (2747) 44.3 (2519)
-Prime: 39.3 (2235) 35.1 (1996)
Radiator Fan Load: kW (hp) 2.8 (3.8) 4.9 (6.6)
Cooling system designed to operate in ambient
conditions up to 50°C (122°F).
Performance 50 Hz 60 Hz
Engine Speed: RPM 1500 1800
Gross Engine Power: kW (hp)
-Standby: 105.0 (141.0) 125.0 (168.0)
-Prime: 95.7 (128.0) 114.0 (153.0)
BMEP: kPa (psi)
-Standby: 1404.0 (203.6) 1393.0 (202.0)
-Prime: 1279.0 (185.5) 1270.0 (184.2)
Regenerative Power: kW 12.6 16.2
LubriCAT-parts-partsion System
Oil Filter Type: Spin-On, Full Flow Total
Oil Capacity l (US gal): 16.1 (4.3)
Oil Pan l (US gal): 13.1 (3.5)
Oil Type: AP1CD 15W-40
Cooling Method: Water
Fuel System
Fuel Filter Type: Replaceable Element Recommended
Fuel: Class A2 Diesel
Fuel Consumption: l/hr (US gal/hr)
110% 100% 75% 50%
Load Load Load Load
P100
50 Hz 25.4 (6.7) 22.8 (6.0) 16.9 (4.5) 11.9 (3.1)
60 Hz 29.2 (7.7) 26.4 (7.0) 20.1 (5.3) 14.7 (3.9)
P110E
50 Hz 25.4 (6.7) 18.6 (4.9) 12.8 (3.4)
60 Hz 29.2 (7.7) 22.1 (5.8) 15.8 (4.2)
(based on diesel fuel with a specific gravity of 0.85
and conforming to BS2869, Class A2)
Exhaust System 50 Hz 60 Hz
Silencer Type: Level 1
Silencer Model & Qty: SD80 (1)
Pressure Drop Across Silencer System: kPa (in Hg) 0.00 (0.000) 0.00 (0.000)
Silencer Noise Reduction Level: dB 18
Max. Allowable Back Pressure: kPa (in. Hg) 6.0 (1.8)
Exhaust Gas Flow: m³/min (cfm)
-Standby: 17.6 (622) 21.9 (773)
-Prime: 16.1 (569) 19.5 (689)
Exhaust Gas Temperature: °C (°F)
m³/min (cfm)
-Standby: 585 (1085) 581 (1077)
-Prime: 550 (1023) 541 (1006)
P100 / P110E
Alternator Performance Data
Data Item |
50 Hz 60 Hz |
||||||||
415/240V |
400/230V 230/115V 200/115V |
380/220V 220/110V |
220/127V |
480/277V 240/139V |
380/220V 220/110V |
240/120V 208/120V |
230/115V |
440/254V 220/127V |
|
Motor Starting Capability* kVA |
187 |
176 |
160 |
208 |
206 |
136 |
160 |
149 |
177 |
Short Circuit Capacity** % |
300 |
300 |
300 |
300 |
300 |
300 |
300 |
300 |
300 |
Reactances: Per Unit
Xd X'd X''d |
3.200
0.120
0.074 |
3.440
0.130
0.080 |
3.810
0.150
0.089 |
2.840
0.110
0.066 |
3.240
0.130
0.075 |
5.080
0.200
0.118 |
4.310
0.170
0.100 |
4.660
0.180
0.108 |
3.850
0.150
0.090 |
Reactances shown are applicable to prime ratings
* Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.
** With optional Permanent Magnet generator or AREP excitation.
Alternator Technical Data
Physical Data Operating Data |
||
Manufacturer: FG WILSON |
Overspeed: RPM 2250 |
|
Model: LL3014B |
Voltage Regulation (steady state) (%): + /- 0.5 |
|
No. of Bearings: 1 |
Wave Form NEMA = TIF: 50 |
|
Insulation Class: H |
Wave Form IEC = THF: 2.0% |
|
Winding Pitch Code: 2/3 - 6 |
Total Harmonic Content LL/LN: 4.0% |
|
Wires: 12 |
Supression is in line with European Standard Radio Interference: EN61000-6 |
|
Ingress Protection Rating: IP23 |
Radiant Heat: kW (Btu/min) -50 Hz: 10.7 (608) -60 Hz: 12.0 (682) |
|
Excitation System: SHUNT |
||
AVR Model: R230 |
P100 / P110E
Technical Data
3 Phase Ratings and Performance at 50 Hz, 1500 RPM
3 Phase Ratings and Performance at 60 Hz, 1800 RPM
Voltage Prime Model Standby Model Voltage Prime Model Standby Model P100 P110E P100 P110E |
|||||
|
kVA kW |
kVA kW |
|
kVA kW |
kVA kW |
415/240V |
100.0 80.0 |
110.0 88.0 |
480/277V |
113.0 90.4 |
125.0 100.0 |
400/230V |
100.0 80.0 |
110.0 88.0 |
220/127V |
113.0 90.4 |
125.0 100.0 |
380/220V |
100.0 80.0 |
110.0 88.0 |
380/220V |
111.0 88.8 |
122.0 97.6 |
230/115V |
100.0 80.0 |
110.0 88.0 |
240/120V |
113.0 90.4 |
125.0 100.0 |
220/127V |
100.0 80.0 |
110.0 88.0 |
230/115V |
113.0 90.4 |
125.0 100.0 |
220/110V |
100.0 80.0 |
110.0 88.0 |
440/254V |
113.0 90.4 |
125.0 100.0 |
200/115V |
100.0 80.0 |
110.0 88.0 |
220/110V |
111.0 88.8 |
122.0 97.6 |
|
|
|
208/120V |
113.0 90.4 |
125.0 100.0 |
|
|
|
230/115V |
113.0 90.4 |
125.0 100.0 |
Definitions
Standby Rating
These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).
Prime Rating
These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Standard Reference Conditions
Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.
Weights and Dimensions
Weights: kg (lb) Dimensions: mm (in)
Net (+ lube oil) |
1240 (2734) |
Length |
2481 (97.7) |
Wet (+ lube oil & coolant) |
1260 (2778) |
Width |
746 (29.4) |
Fuel, lube oil & coolant |
1454 (3206) |
Height |
1435 (56.5) |
General Data
Documents
A full set of operation and maintenance manuals, circuit wiring diagrams, and commissioning/fault finding instruction leaflets.
Generating Set Standards
The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, VDE 0530, NEMA MG-1.22.
Warranty
All equipment carries full manufacturer's warranty.