• Guangdong ALI Testing Equipment Co,.Ltd
    K.S. LIM
    Your genset and ATS are working well. I have given your name and email to a friend who will be building a hotel in Palawan. Thanks,
  • Guangdong ALI Testing Equipment Co,.Ltd
    Waleed-Egypt
    Thanks always giving me good products. thanks for your effort you done before. your firend from Egypt.
  • Guangdong ALI Testing Equipment Co,.Ltd
    Akakulubelwa Mwiyakui-Zambia
    I must confess you have a brilliant customer relations skills and i am learning from you. I tell you if you want to see how beautiful Zambia in Africa
Contact Person : Kris
Phone Number : 0086-0769-85914911
WhatsApp : +8618046939311

1800 rpm Diesel Generator , 60 hz , Perkins 1006TG2A , Turbocharged

Place of Origin China
Brand Name GSKA
Model Number JP- P110E
Minimum Order Quantity 20-30 pieces
Price Negotiable
Packaging Details Standard plywood and wood package.the actual package size against goods size and handle requires.
Delivery Time 3-5 days on receipt of official sales contract
Payment Terms L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal
Supply Ability 500 pieces per Month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
High Light

standby diesel generator

,

diesel generators sets

Leave a Message
Product Description

 

 

Manufacturer:                             Perkins

Model:                                       1006TG2A

No. of Cylinders/Alignment:  6 / In Line

Cycle:                                          4 Stroke

Induction:                              Turbocharged

Cooling Method:                          Water

Governing Type:                     Mechanical

Governing Class:                ISO 8528 G2
Compression Ratio:                  16.0:1

 

Output Ratings

Generating Set Model

 

* JPP110E Prime* Standby*

 

380-415V, 50 Hz

 

100.0 kVA 110.0 kVA

80.0 kW 88.0 kW

 

480V, 60 Hz

 

113.0 kVA 125.0 kVA

90.4 kW 100.0 kW

* Refer to ratings definitions on page 4.

Ratings at 0.8 power factor.

 

Technical Data

Engine Make & Model:

Perkins 1006TG2A

Alternator Model:

LL3014B

Base Frame Type:

Heavy Duty FabriCAT-parts-partsed Steel

Circuit Breaker Type:

3 Pole MCB / 3 Pole MCCB

Frequency:

50 Hz 60 Hz

Engine Speed: RPM

1500 1800

Fuel Tank Capacity: litres (US gal)

230 (60.8)

Fuel Consumption: P100 l/hr (US gal/hr)

22.8 (6.0) 26.4 (7.0)

Fuel Consumption: P110E  l/hr (US gal/hr)

25.4 (6.7) 29.2 (7.7)

P100 / P110E

 

Engine Technical Data

 

Physical Data

Manufacturer:                                                Perkins

Model:                                                         1006TG2A

No. of Cylinders/Alignment:                     6 / In Line

Cycle:                                                             4 Stroke

Induction:                                                 Turbocharged

Cooling Method:                                             Water

Governing Type:                                        Mechanical

Governing Class:                                    ISO 8528 G2
Compression Ratio:                                    16.0:1

Displacement: l (cu.in)                             6.0 (365.5)

Bore/Stroke: mm (in)                       100.0 (3.9)/127.0 (5.0)

Moment of Inertia: kg m² (lb. in²)            1.61 (5502)

Engine Electrical System:

-Voltage/Ground:                                      12/Negative

-Battery Charger Amps:                                    55

Weight: kg (lb) - Dry:                                 586 (1292)

- Wet:                                                           623 (1373)

 

Air System                                                     50 Hz                                                                            60 Hz

Air Filter Type:                                                                                     Replaceable 

Element Combustion Air Flow:m³/min (cfm)

-Standby:                                                    6.0 (212)                                                                       7.6 (268)

-Prime:                                                        5.7 (201)                                                                       7.2 (254) 

Max. Combustion Air Intake

Restriction: kPa (in H2O)                       5.0 (20.1)                                                                      5.0 (20.1) 

Radiator Cooling Air Flow:m³/min (cfm)                          192.0 (6780)   244.0 (8617) 

External Restriction to Cooling Air Flow: Pa (in H2O)           125 (0.5) 125 (0.5)

 

Cooling System                                           50Hz                                                                              60 Hz

 

Cooling System Capacity: l (US gal)   27.7 (7.3)                                                                       27.7 (7.3) 

Water Pump Type:                                                                            Centrifugal

Heat Rejected to Water & Lube Oil: kW (Btu/min)

-Standby:                                                69.8 (3969)                                                                   78.8 (4481)

-Prime:                                                    62.6 (3560)                                                                   70.8 (4026) 

Heat Radiation to Room:

kW (Btu/min) -Standby:                        48.3 (2747)                                                                   44.3 (2519)

-Prime:                                                    39.3 (2235)                                                                   35.1 (1996) 

Radiator Fan Load: kW (hp)                     2.8 (3.8)                                                                          4.9 (6.6)

Cooling system designed to operate in ambient 

conditions up to 50°C (122°F).

 

Performance                                                50 Hz                                                                            60 Hz

 

Engine Speed: RPM                                    1500                                                                             1800

Gross Engine Power: kW (hp)

-Standby:                                                105.0 (141.0)                                                               125.0 (168.0)

-Prime:                                                      95.7 (128.0)                                                               114.0 (153.0) 

BMEP: kPa (psi)

-Standby:                                              1404.0 (203.6)                                                             1393.0 (202.0)

-Prime:                                                  1279.0 (185.5)                                                             1270.0 (184.2) 

Regenerative Power: kW                           12.6                                                                                  16.2

 

LubriCAT-parts-partsion System

 

Oil Filter Type:                                                       Spin-On, Full Flow Total 

Oil Capacity l (US gal):                                                    16.1 (4.3)

Oil Pan l (US gal):                                                            13.1 (3.5)

Oil Type:                                                                       AP1CD 15W-40

Cooling Method:                                                                 Water

 

Fuel System

 

Fuel Filter Type:                                        Replaceable Element Recommended 

Fuel:                                                                              Class A2 Diesel

Fuel Consumption: l/hr (US gal/hr)

 

110% 100% 75%  50% 

Load  Load  Load Load

P100

 

50 Hz  25.4 (6.7) 22.8 (6.0) 16.9 (4.5) 11.9 (3.1)

60 Hz  29.2 (7.7) 26.4 (7.0) 20.1 (5.3) 14.7 (3.9)

P110E

 

50 Hz  25.4 (6.7) 18.6 (4.9) 12.8 (3.4)

60 Hz  29.2 (7.7) 22.1 (5.8) 15.8 (4.2)

 

(based on diesel fuel with a specific gravity of 0.85 

and conforming to BS2869, Class A2)

 

Exhaust System                                           50 Hz                                                                            60 Hz

 

Silencer Type:                                                                                          Level 1

Silencer Model & Qty:                                                                            SD80 (1) 

Pressure Drop Across Silencer System: kPa (in Hg)      0.00 (0.000) 0.00 (0.000) 

Silencer Noise Reduction Level: dB                                                       18

Max. Allowable Back Pressure: kPa (in. Hg)                                     6.0 (1.8) 

Exhaust Gas Flow: m³/min (cfm)

-Standby:                                                 17.6 (622)                                                                    21.9 (773)

-Prime:                                                     16.1 (569)                                                                    19.5 (689) 

Exhaust Gas Temperature:  °C (°F)

m³/min (cfm)

-Standby:                                                 585 (1085)                                                                  581 (1077)

-Prime:                                                     550 (1023)                                                                  541 (1006)

P100 / P110E

 

Alternator Performance Data

 

 

 

Data Item

50 Hz 60 Hz

415/240V

400/230V

230/115V

200/115V

380/220V

220/110V

220/127V

480/277V

240/139V

380/220V

220/110V

240/120V

208/120V

230/115V

440/254V

220/127V

 

 

Motor Starting Capability* kVA

 

 

187

 

 

176

 

 

160

 

 

208

 

 

206

 

 

136

 

 

 

160

 

 

149

 

 

177

 

 

Short Circuit Capacity** %

 

 

 

300

 

 

 

300

 

 

 

300

 

 

 

300

 

 

 

300

 

 

 

300

 

 

 

300

 

 

 

300

 

 

 

300

 

 

Reactances: Per Unit

 

 

Xd X'd X''d

3.200

 

0.120

 

0.074

3.440

 

0.130

 

0.080

3.810

 

0.150

 

0.089

2.840

 

0.110

 

0.066

3.240

 

0.130

 

0.075

5.080

 

0.200

 

0.118

4.310

 

0.170

 

0.100

4.660

 

0.180

 

0.108

3.850

 

0.150

 

0.090

 

Reactances shown are applicable to prime ratings

* Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.

** With optional Permanent Magnet generator or AREP excitation.

 

Alternator Technical Data

 

Physical Data Operating Data

Manufacturer: FG WILSON

Overspeed: RPM 2250

Model: LL3014B

Voltage Regulation (steady state) (%): + /- 0.5

No. of Bearings: 1

Wave Form NEMA = TIF: 50

Insulation Class: H

Wave Form IEC = THF: 2.0%

Winding Pitch Code: 2/3 - 6

Total Harmonic Content LL/LN: 4.0%

Wires: 12

Supression is in line with European Standard

Radio Interference: EN61000-6

Ingress Protection Rating: IP23

Radiant Heat: kW (Btu/min)

-50 Hz: 10.7 (608)

-60 Hz: 12.0 (682)

Excitation System: SHUNT

AVR Model: R230

P100 / P110E

 

Technical Data

 

3 Phase Ratings and Performance at 50 Hz, 1500 RPM

3 Phase Ratings and Performance at 60 Hz, 1800 RPM

 

Voltage          Prime Model         Standby Model          Voltage      Prime Model       Standby Model

                            P100                       P110E                                   P100                    P110E

 

kVA kW

kVA kW

 

kVA kW

kVA kW

415/240V

100.0 80.0

110.0 88.0

480/277V

113.0 90.4

125.0 100.0

400/230V

100.0 80.0

110.0 88.0

220/127V

113.0 90.4

125.0 100.0

380/220V

100.0 80.0

110.0 88.0

380/220V

111.0 88.8

122.0 97.6

230/115V

100.0 80.0

110.0 88.0

240/120V

113.0 90.4

125.0 100.0

220/127V

100.0 80.0

110.0 88.0

230/115V

113.0 90.4

125.0 100.0

220/110V

100.0 80.0

110.0 88.0

440/254V

113.0 90.4

125.0 100.0

200/115V

100.0 80.0

110.0 88.0

220/110V

111.0 88.8

122.0 97.6

 

 

 

208/120V

113.0 90.4

125.0 100.0

 

 

 

230/115V

113.0 90.4

125.0 100.0

 

Definitions

 

Standby Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).

 

Prime Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

 

Standard Reference Conditions

Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.

 

1800 rpm Diesel Generator , 60 hz , Perkins 1006TG2A , Turbocharged 0

 

Weights and Dimensions

 

Weights: kg (lb) Dimensions: mm (in)

 

 

Net (+ lube oil)

 

1240 (2734)

 

Length

 

2481 (97.7)

Wet (+ lube oil & coolant)

1260 (2778)

Width

746 (29.4)

Fuel, lube oil & coolant

1454 (3206)

Height

1435 (56.5)

 

General Data

 

Documents

A full set of operation and maintenance manuals, circuit wiring diagrams, and commissioning/fault finding instruction leaflets.

 

Generating Set Standards

The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, VDE 0530, NEMA MG-1.22.

 

Warranty

All equipment carries full manufacturer's warranty.