• Guangdong ALI Testing Equipment Co,.Ltd
    K.S. LIM
    Your genset and ATS are working well. I have given your name and email to a friend who will be building a hotel in Palawan. Thanks,
  • Guangdong ALI Testing Equipment Co,.Ltd
    Waleed-Egypt
    Thanks always giving me good products. thanks for your effort you done before. your firend from Egypt.
  • Guangdong ALI Testing Equipment Co,.Ltd
    Akakulubelwa Mwiyakui-Zambia
    I must confess you have a brilliant customer relations skills and i am learning from you. I tell you if you want to see how beautiful Zambia in Africa
Contact Person : Kris
Phone Number : 0086-0769-85914911
WhatsApp : +8618046939311

4 Stroke Mechanical Perkins Generators , 11KW , 403C-15 , LL1014H

Place of Origin China
Brand Name GSKA
Model Number JP-P13.5E2
Minimum Order Quantity 20-30 pieces
Price Negotiable
Packaging Details Standard plywood and wood package.the actual package size against goods size and handle requires.
Delivery Time 3-5 days on receipt of official sales contract
Payment Terms L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal
Supply Ability 500 pieces per Month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
High Light

standby diesel generator

,

diesel generators sets

Leave a Message
Product Description

 

1. Standby power:                                           11 kw

2.Engine Make & Model:                        Perkins 403C-15

3.Alternator Model:                                       LL1014H

4.Fuel Tank Capacity:                       litres (US gal):45 (11.9)

5.Compression Ratio:                                     22.5:1

6.Displacement: l (cu.in)                              1.5 (91.3)

7.Bore/Stroke: mm (in)                        84.0 (3.3)/90.0 (3.5)

8.Moment of Inertia: kg m² (lb. in²):            2.50 (8543) 

9.Circuit Breaker Type:                             3 Pole MCB

10.dimensions(mm)*in:          1320 (52.0)*552 (21.7)*1258 (49.5) mm

 

Output Ratings

Generating Set Model

 

  JPP13.5E2

Prime*                     Standby*

 

380-415V, 50 Hz

 

12.5 kVA                  13.8 kVA

10.0 kW                   11.0 kW

 

220/127V, 60 Hz

 

15.0 kVA                  16.2 kVA

12.0 kW                   13.0 kW

  • Refer to ratings definitions on page 4.

           Ratings at 0.8 power factor.

 

Technical Data

Engine Make & Model:

Perkins 403C-15

Alternator Model:

LL1014H

Base Frame Type:

Heavy Duty FabriCAT-parts-partsed Steel

Circuit Breaker Type:

3 Pole MCB

Frequency:

50 Hz           60 Hz

Engine Speed: RPM

1500                1800

Fuel Tank Capacity: litres (US gal)

45 (11.9)

Fuel Consumption:   P12.5P2  l/hr (US gal/hr)

3.7 (1.0)           4.3 (1.1)

Fuel Consumption:   P13.5E2   l/hr (US gal/hr)

4.1 (1.1)           4.7 (1.2)


 

P12.5P2 / P13.5E2

 

Engine Technical Data

 

Physical Data  

 

Manufacturer:                                   Perkins

Model:                                             403C-15

No. of Cylinders/Alignment:            3 / In Line

Cycle:                                             4 Stroke

Induction:                                 Naturally Aspirated

Cooling Method:                              Water

Governing Type:                          Mechanical

Governing Class:                        ISO 8528 G2

Compression Ratio:                         22.5:1

Displacement: l (cu.in)                  1.5 (91.3)

Bore/Stroke: mm (in)             84.0 (3.3)/90.0 (3.5)

Moment of Inertia: kg m² (lb. in²)   2.50 (8543)

Engine Electrical System:

-Voltage/Ground:                        12/Negative

-Battery Charger Amps:                     55

Weight: kg (lb)

- Dry:                                           197 (434)

- Wet:                                          208 (459)

 

 

Air System                                    50 Hz                                                       60 Hz

 

Air Filter Type:                                                         Replaceable

Element Combustion Air Flow:m³/min (cfm)       

-Standby:                                     1.1 (39)                                                     1.3 (46)

-Prime:                                         1.1 (39)                                                     1.3 (46)

Max. Combustion Air Intake Restriction: kPa (in H2O)       6.4 (25.7)          6.4 (25.7)

Radiator Cooling Air Flow: m³/min (cfm)                            26.0 (918)      35.0 (1236)

External Restriction to Cooling Air Flow: Pa (in H2O)          125 (0.5)          125 (0.5)

 

Cooling System                            50 Hz                                                       60 Hz

 

Cooling System Capacity: l (US gal)                            5.8 (1.5)    

Water Pump Type:  Centrifugal

Heat Rejected to Water & Lube Oil: kW (Btu/min)

-Standby:                                     12.8 (728)                                              15.4 (876)

-Prime:                                         11.5 (654)                                              14.2 (808)

Heat Radiation to Room:kW (Btu/min)       

-Standby:                                       5.8 (330)                                                6.9 (392)

-Prime:                                           5.2 (296)                                                6.4 (364)

Radiator Fan Load: kW (hp)           0.2 (0.2)                                                 0.3 (0.4)

Cooling system designed to operate in ambient conditions up to 50°C (122°F).

 

Performance                                50 Hz                                                        60 Hz

 

Engine Speed: RPM                      1500                                                          1800

Gross Engine Power: kW (hp)

-Standby:                                 13.5 (18.0)                                                 16.2 (22.0)

-Prime:                                     12.2 (16.0)                                                 14.7 (20.0)

BMEP: kPa (psi)

-Standby:                             722.0 (104.7)                                             722.0 (104.7)

-Prime:                                   652.0 (94.6)                                               655.0 (95.0)

Regenerative Power: kW               4.5                                                              5.8

 

LubriCAT-parts-partsion System

 

Oil Filter Type:                                               Spin-On, Full Flow

Total Oil Capacity l (US gal):                                6.0 (1.6)

Oil Pan l (US gal):                                                 4.5 (1.2)

Oil Type:                                                        AP1CH4 15W-40

Cooling Method:                                                     Water

 

Fuel System

 

Fuel Filter Type:                         Replaceable Element Recommended

Fuel:                                                               Class A2 Diesel

Fuel Consumption: l/hr (US gal/hr)

110%              100%               75%                50%

Load               Load               Load               Load

P12.5P2

 

50 Hz          4.1 (1.1)          3.7 (1.0)          2.8 (0.7)          2.1 (0.6)

60 Hz          4.7 (1.2)          4.3 (1.1)          3.2 (0.8)          2.4 (0.6)

P13.5E2

 

50 Hz   4.1 (1.1)          3.0 (0.8)          2.2 (0.6)

60 Hz   4.7 (1.2)          3.5 (0.9)          2.5 (0.7)

 

(based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)

 

Exhaust System                           50 Hz                                                       60 Hz

 

Silencer Type:                                                             Level 1

Silencer Model & Qty:                                             MXC0996 (1)

Pressure Drop Across Silencer System: kPa (in Hg)       1.80 (0.532)     0.00 (0.000)

Silencer Noise Reduction Level: dB   

Max. Allowable Back Pressure: kPa (in. Hg)                        10.2 (3.0)         10.2 (3.0)

Exhaust Gas Flow: m³/min (cfm)       

-Standby:                                                                               2.8 (99)           3.5 (124)

-Prime:                                                                                   2.6 (92)           3.4 (120)

Exhaust Gas Temperature:  °C (°F)

m³/min (cfm)       

-Standby:                                                                             491 (916)         504 (938)

-Prime:                                                                                 446 (834)         456 (852)

 

Alternator Performance Data

Data Item

          50 Hz                                60 Hz

415/240V

400/230V

380/220V

440/254V

220/127V

Motor Starting Capability* kVA

 

 

25

 

 

24

 

 

22

 

 

24

Short Circuit Capacity** %

0

0

0

0

Reactances: Per Unit

Xd X'd X''d

1.790

 

0.130

 

0.066

1.920

 

0.140

 

0.071

2.130

 

0.160

 

0.079

2.290

 

0.170

 

0.085

 

Reactances shown are applicable to prime ratings

  • Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.

** With optional Permanent Magnet generator or AREP excitation.

 

Alternator Technical Data

 

Physical Data                                                                   Operating Data

Manufacturer:   FG WILSON

Overspeed: RPM        2250

Model:  LL1014H

Voltage Regulation (steady state) (%):   + /- 0.5

No. of Bearings: 1

Wave Form NEMA = TIF:   50

Insulation Class:  H

Wave Form IEC = THF:  2.0%

Winding Pitch Code:   2/3 - 6

Total Harmonic Content LL/LN: 4.0%

Wires:   12

Supression is in line with European Standard

Radio Interference:       EN61000-6

Ingress Protection Rating: IP23

Radiant Heat: kW (Btu/min)

-50 Hz:   2.3 (131)

-60 Hz:     2.6 (148)

Excitation System:   SHUNT

AVR Model: R230

 

P12.5P2 / P13.5E2


 

Technical Data

 

3 Phase Ratings and Performance at 50 Hz, 1500 RPM

3 Phase Ratings and Performance at 60 Hz, 1800 RPM

 

 

Voltage         Prime Model       Standby Model          Voltage          Prime Model                Standby Model

                       P12.5P2              P13.5E2                                       P12.5P2                      P13.5E2

 

kVA                 kW

kVA                 kW

 

kVA                 kW

kVA                  kW

415/240V

12.5                10.0

13.8                11.0

 

 

 

400/230V

12.5                10.0

13.8                11.0

220/127V

15.0                12.0

16.2                13.0

380/220V

12.5                10.0

13.7                11.0

 

 

 

 

 

 

440/254V

-                      -

-                      -

 

 

Definitions

 

Standby Rating

 

These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).

 

Prime Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

 

Standard Reference Conditions

Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.

 

 

4 Stroke Mechanical Perkins Generators , 11KW , 403C-15 , LL1014H 0

 

Weights and Dimensions

 

Weights: kg (lb)                               Dimensions: mm (in)

Net (+ lube oil)                       

396 (873)

Length

1320 (52.0)

Wet (+ lube oil & coolant)

402 (886)

Width

552 (21.7)

Fuel, lube oil & coolant

440 (970)

Height

1258 (49.5)