• Guangdong ALI Testing Equipment Co,.Ltd
    K.S. LIM
    Your genset and ATS are working well. I have given your name and email to a friend who will be building a hotel in Palawan. Thanks,
  • Guangdong ALI Testing Equipment Co,.Ltd
    Waleed-Egypt
    Thanks always giving me good products. thanks for your effort you done before. your firend from Egypt.
  • Guangdong ALI Testing Equipment Co,.Ltd
    Akakulubelwa Mwiyakui-Zambia
    I must confess you have a brilliant customer relations skills and i am learning from you. I tell you if you want to see how beautiful Zambia in Africa
Contact Person : Kris
Phone Number : 0086-0769-85914911
WhatsApp : +8618046939311

100 Kva-550kva Perkins Engine Generator , Perkins Diesel Power Generator, Perkins Diesel Generator Set

Place of Origin China
Brand Name GSKA
Model Number JP-P605E5
Minimum Order Quantity 20-30 pieces
Price Negotiable
Packaging Details Standard plywood and wood package.the actual package size against goods size and handle requires.
Delivery Time 3-5 days on receipt of official sales contract
Payment Terms L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal
Supply Ability 500 pieces per Month

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Product Name Perkins 2 Cylinder Diesel Generator Type Silent/Open
Engine Kubota/Cummins/Perkins Etc. Options ABB/ATS/Container/Trailer
Control Panel Deepsea / ComAp Engine Model UK Perkins 2506C-E15TAG2
Warranty 12 Months/1000 Hours Rated Voltage 400/230V
High Light

diesel generators sets

,

portable diesel powered generators

Leave a Message
Product Description

 

100 Kva-550kva Perkins Engine Generator , 250 Kva Perkins Diesel Generator

 

 

Product Description

 

1. Standby power: 484.0 KW

2. Engine Make & Model:Perkins 2806A-E18TAG1

3.Cooling Method:            Water Governing

4.Type:                             Electronic Governing

5.Class:                                     ISO 8528 G2

6.Compression Ratio:               14.5:1

7.Displacement: l (cu.in)         18.1 (1104.5) 

 

 

4 Stroke 550kVA Perkins Engine Generator, P605E5

 

Output Ratings   P605E5

Generating Set Model

Prime*                           Standby*

380-415V,50Hz

550.0 kVA                     605.0 kVA

440.0 kW                      484.0 kW

  • Refer to ratings definitions on page 4.  Ratings at 0.8 power factor.

Technical Data

Engine Make & Model:

Perkins 2806A-E18TAG1

Alternator Model:

LL6114G

Base Frame Type:

Heavy Duty FabriCAT-parts-partsed Steel

Circuit Breaker Type:

3 Pole ACB/MCCB

Frequency:

50 Hz           60 Hz

Engine Speed: RPM

1500                    -

Fuel Tank Capacity: litres (US gal)

1000 (264.2)

Fuel Consumption       P550P5          : l/hr (US gal/hr)

110.8 (29.3)               -

Fuel Consumption        P605E5          : l/hr (US gal/hr)

122.5 (32.4)               -

 

Engine Technical Data

 

Physical Data

1. Manufacturer:      Perkins

2. Model:    2806A-E18TAG1

3. No. of Cylinders/Alignment:   6 / In Line

4. Cycle:   4 Stroke

5. Induction:  Turbo charged Air To Air Charge Cooled

6. Cooling Method: Water Governing

7. Type:   Electronic

8. Governing Class:    ISO 8528 G2

9. Compression Ratio:  14.5:1

10. Displacement: l (cu.in) 18.1 (1104.5)

11. Bore/Stroke: mm (in)  145.0 (5.7)/183.0 (7.2) 

12. Moment of Inertia: kg m² (lb. in²)    7.44 (25424)

 

 

Engine Electrical System:

-Voltage/Ground:  24/Negative

-Battery Charger Amps:    70

Weight: kg (lb)

- Dry:    2050 (4519)

- Wet:   2158 (4758)

 

Air System    50 Hz           60 Hz

Air Filter Type:Replaceable Element Combustion

Air Flow:m³/min (cfm)      

-Standby:     24.9 (879)              

-Prime:    22.8 (805)              

- Max. Combustion Air Intake Restriction: kPa (in H2O)    6.3 (25.3)                

- Radiator Cooling Air Flow: m³/min (cfm)      660.0 (23308)            

- External Restriction to Cooling Air Flow: Pa (in H2O) 125 (0.5)      

  

Cooling System   50 Hz    60 Hz       

Cooling System Capacity: (US gal) 61.0 (16.1)               

- Water Pump Type:  Centrifugal

Heat Rejected to Water &Lube Oil: kW (Btu/min)

-Standby:            138.7 (7888)             

-Prime:             133.3 (7581)             

- Heat Radiation to Room:

kW (Btu/min)        

-Standby:            34.5 (1962)               

-Prime:              30.9 (1757)               

- Radiator Fan Load: kW (hp)      8.0 (10.7)               

Cooling system designed to operate in ambient conditions up to 50°C (122°F).

Contact your local FG Wilson dealer for power ratings at specific site conditions.

 

Performance    50 Hz         60 Hz

Engine Speed: RPM   1500                       

- Gross Engine Power: kW (hp)

-Standby:        544.0 (730.0)                

-Prime:         495.0 (664.0)                

- BMEP: kPa (psi)

-Standby:       2400.0 (348.1)               

-Prime:        2184.0 (316.8)               

- Regenerative Power: kW  20.0                       

 

 

LubriCAT-parts-partsion System

Oil Filter Type: Eco, Full Flow

Total Oil Capacity l (US gal):  55.5 (14.7)

Oil Pan l (US gal): 53.5 (14.1)

Oil Type: API CH4 / CI4

Cooling Method:   Water

 

Fuel System

Fuel Filter Type:  Eco Replaceable

Element Recommended Fuel:Class A2 Diesel

Fuel Consumption: l/hr (US gal/hr)

110%              100%               75%                50%

Load               Load               Load               Load

P550P5

 

50 Hz      122.3 (32.3)    110.8 (29.3) 83.9 (22.2)       59.2 (15.6)

60 Hz               -                      -                       -                      -

P605E5

50 Hz                              122.5 (32.4)      91.9 (24.3)       64.2 (17.0)

60 Hz                                      -                       -                      -

(based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)

 

Exhaust System   50 Hz           60 Hz

Silencer Type:      Level 1

Silencer Model & Qty:    SD200 (1) Pressure Drop Across

Silencer System: kPa (in Hg)               0.15 (0.044)               - Silencer Noise Reduction

Level: dB                                                     11                       - Max. Allowable Back

Pressure: kPa (in. Hg)                            6.8 (2.0)                 - Exhaust Gas Flow:

m³/min (cfm)       -Standby:            109.0 (3849)              -

-Prime:             109.0 (3849)              - Exhaust Gas Temperature:  °C (°F)

m³/min (cfm)       -Standby:              550 (1022)                -

-Prime:               550 (1022)                -

P550P5 / P605E5

 

 

Alternator Performance Data

Data Item

                                  50 Hz                                            

415/240V

400/230V

380/220V

Motor Starting Capability* kVA

1311

1227

1117

Short Circuit Capacity** %

300

300

300

Reactances: Per Unit

 

 

Xd X'd X''d

3.340

0.170

 

0.120

3.600

 

0.180

 

0.129

3.990

 

0.200

 

0.143

 

Reactances shown are applicable to prime ratings

  • Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.

** With optional Permanent Magnet generator or AREP excitation.

 

 

Alternator Technical Data

Physical Data                                                                    Operating Data

Manufacturer:   FG WILSON

Overspeed: RPM   2250

Model:    LL6114G

Voltage Regulation (steady state) (%):   +/- 0.5

No. of Bearings:    1

Wave Form NEMA = TIF:  50

Insulation Class:    H

Wave Form IEC = THF: 2.0%

Winding Pitch Code:     2/3 - 6

Total Harmonic Content LL/LN:    2.0%

Wires:    12

Supression is in line with European Standard

Radio Interference:     EN61000-6

Ingress Protection Rating:   IP23

Radiant Heat: kW (Btu/min)

-50 Hz:                                   30.3 (1723)

-60 Hz:                                            -

Excitation System:  SHUNT

AVR Model:     R448

 

 

Technical Data

3 Phase Ratings and Performance at 50 Hz, 1500 RPM

3 Phase Ratings and Performance at 60 Hz,-    RPM

 

 

Definitions

Standby Rating

 

These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).

 

 

Prime Rating

 

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

 

Standard Reference Conditions

 

Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.

 


 


100 Kva-550kva Perkins Engine Generator , Perkins Diesel Power Generator, Perkins Diesel Generator Set 0

 

 

Weights and Dimensions

 

Weights: kg (lb)                                                             Dimensions: mm (in)

Net (+ lube oil)

4655 (10263)

Length

4111 (161.9)

Wet (+ lube oil & coolant)

4725 (10417)

Width

1536 (60.5)

Fuel, lube oil & coolant

5866 (12932)

Height

2246 (88.4)

 

 

General Data

 

Documents

A full set of operation and maintenance manuals, circuit wiring diagrams, and commissioning/fault finding instruction leaflets.

 

Generating Set Standards

The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, VDE 0530, NEMA MG-1.22.

 

 

Warranty

All equipment carries full manufacturer's warranty.